Rooftop Screens
Rooftop Screens
Roofed Enclosures
Enclosures & Gates
naturescreen_nav3
NatureScreen®
Marquee_Canopy_FlatSoffittAssembly_NavBarImage-1
Canopies & Awnings
View All Products
View All...
Envisor
MOST POPULAR
Unit-attached

Vertical Rib

INFILL MATERIAL: Acrylicap® ABS
Vertical Rib
Back to main options
TRIM OPTIONS
+ Finishing trim for your screen edges
COLOR OPTIONS
color-palette + Standard Powder-Coat
BUILT TO ALIGN WITH YOUR DESIGN INTENT.
Project-specific sizes, custom colors, and finishes available.
Get a Quote chevron-right Get all files and downloads

Each screening system is configured around project-specific structural, wind, airflow, access and sightline requirements. Engineering support and PE-stamped drawings are available where required.

OVERVIEW

 Acrylicap® ABS is a proprietary material developed by CityScapes. We start with a matching color ABS core, then laminate an acrylic outer layer to both sides of the sheet to provide a strong barrier against UV degradation. The result: superior color retention. 

KEY FEATURES
  • Acrylicap ABS uses .187 acrylic-capped ABS for UV protection
  • Frames are 6063 T6 extruded aluminum
  • Wind Load / Wind Resistance 115mph - 180mph
  • Mold and Mildew Resistance

DOWNLOADS

Brochures

  • Envisor Brochure PDF

Sell Sheet

  • Envisor Sell Sheet PDF
  • Envisor Z-Fin Sell Sheet PDF

Installation Instructions

  • Envisor Unit Attached Installation Manual PDF
  • Envisor Installation Video VIEW
  • Envisor Post Mounted Installation Instructions PDF

Warranties

  • Envisor Standard Limited Warranty PDF

Frequently Asked Questions

BIM / REVIT

  • Start by downloading our design files from CADdetails.com or ARCAT.com
  • Envisor Unit Attached Screens RFA
  • Envisor Post Mounted Screens RFA
  • Envisor Z-Fin Louvered Post Mounted Screens RFA

Specs

Drawings

  • Envisor 35” Unit Attached Screens PDF CAD
  • Envisor 52” Unit Attached Screens PDF CAD
  • Envisor 70” Unit Attached Screens PDF CAD
  • Envisor Z-Fin  PDF CAD
  • Envisor Z-Fin with door PDF CAD
  • Envisor Z-Fin Box Corner With Door PDF CAD
  • Envisor Z-Fin Box Corner PDF CAD

Municipal Code Reference

FREQUENTLY ASKED QUESTIONS

1. DO THE ENVISOR PRODUCTS HAVE ANY EFFECT ON THE WARRANTY OF THE EQUIPMENT THEY SCREEN?

We have not had any equipment manufacturer indicate the addition of Envisor screens will void their warranty. Additionally, we have worked closely with major suppliers to accommodate any concerns and gain their approvals.

2. IS AIRFLOW TO THE RTU IMPEDED BY THE ADDITION OF AN ENVISOR EQUIPMENT SCREEN?

No, our engineers design project-specific accommodations for any RTU performance features added to each piece of equipment.

3. WHAT ARE THE REQUIREMENTS FOR POST MOUNTED SCREENING?

Envisor Post Mounted screening is designed to easily attach to existing roof posts. CityScapes scope of work does not include creating structural steel plan, providing posts, or installing posts on the roof. It is recommended to review post layout and roof load requirements with a structural engineer. Posts are required be 4x4 steel ¼ inch thickness.  Round stock may be used if 3 inches in diameter and ¼ inch thick. Posts should be set no more than 8 feet on center, at or above the height of the tallest HVAC unit. For new builds opting for  Envisor Post Mounted systems, post height should be chosen accommodate Panel height (35", 52" or 70"), minimum 6" at the bottom for airflow, and 4" for each frame. If additional coverage is required, panels can be stacked two layers for additional coverage. For a stacked 35”/52” we would recommend posts be at least 101" tall - 87" for the panels plus 8" for the frames and an additional 6" minimum at the screen bottom for proper airflow.

4. CAN I SCREEN MULTIPLE PIECES OF EQUIPMENT ON A ROOFTOP TOGETHER WITH UNIT ATTACHED SCREENING?

Yes, however, the RTUs must be positioned close enough to each other to allow for “nesting". To conceal/nest two more units within one united-attached screen system - all 5 of the following criteria must be met. 

1) units must be able to be concealed with a unit-attached screen system
2) units must be of similar height (less 6" difference)
3) units must be in line (less than 12" offset)
4) units must be less than 96" apart
5) units must not be on vibration isolation springs /curbs


5. WHAT ARE THE PRODUCT’S WIND LOAD SPECIFICATIONS?

We have had a licensed engineer stamp product drawings to meet 180-mph wind load requirements with some product modifications. Generally, our engineers allow for an ultimate wind load of 115-mph. In high wind load areas, it is required for unit attached screens to be four sided. In Florida and Hawaii Beachfront projects within 1500 ft of the water must be Post-Mounted. To meet wind load requirements any metal panel may be chosen but the only approved ABS panel style is vertical rib. 

Specs & files coming soon.

Request spec + details

GET PRICING FASTER?

Set your rooftop screen specs here — it's that simple.

 

More categories

  • Covrit-1111RT-Single-Roofed-Enclosure-with-transom-vertical-plankwall-apartment-complex
    Covrit® Enclosures & Screens
  • Marquee-Canopies-and-Awnings-cantilever-Canopy-commercial
    Canopies & Awnings
  • Sanctum-Hospitality-Royale-Double-Cabana-hotel-resort
    Cabanas & Hospitality
  • Naturescreen-plant-trellis-system-wall-mounted-Parking-Garage
    NatureScreen®
  • ToughGate-Gates-and-Doors-Metal-Slatwall-6-Inch-Vertical
    Commercial Gates & Doors
18e7a8101a73e35a2450ba2db6cd6deb8088ecda

READY TO DISCUSS YOUR NEXT PROJECT?

Connecting with one of our project managers is easy. Reach out today to get started.